40 KHz resolution

One (and only one) of the 6 units has been retrofitted to offer a higher frequency resolution (40 kHz instead of 80 kHz). This is obtained by operating at half clock speed and inserting an anti-aliasing filter of effective bandwidth 8 MHz. Because the filter reduces the input power to the sampler, this unit should be placed near the maximum amplitude of the IF bandpass: band edges must be avoided.