Next: 11.1.2 Before starting the
Up: 11.1 Introduction
Previous: 11.1 Introduction
At the first login on a new project account, you should find five directories:
- 1.
- reports: It contains all the pre-calibration performed by the
Astronomer on Duty (AoD) on the site. This subdirectory is in read access only. For
a given observing date, you should find the following compressed files:
28-feb-2001-x007.hpb.gz, the header file containing the calibration curves
of the data; 28-feb-2001-x007.ps.gz, the PostScript file containing the
result of this calibration. This file should be carefully read before starting a new
calibration. show-28-feb-2001-x007.ps.gz is the PostScript file
corresponding to a first look of the data. It includes meteo conditions (wind, mm of
water, system temperature) but also pointing and focus errors. In many cases, this
file can help to interpret dubious data. This file should also be read carefully
before starting calibration. The file x007.note are notes written by the
AoD on the site. This file is updated at each period of observations. It gives
important information about the data quality and possible problems.
- 2.
- headers: It initially contains a copy of reports. Files should
be uncompressed and data calibration should be performed in this subdirectory. This
is the default directory of CLIC. However before activating CLIC, it is better to
move to this subdirectory using the shell command: ``cd /headers''.
- 3.
- maps: This subdirectory, empty at the beginning, should contain
at the end all the uv tables and the maps produced. Using the CLICprocedure ``Write A UV Table'', the uv tables are created by default in this directory
which is also the default directory for GRAPHIC and MAPPING.
- 4.
- tmp/DATA: This subdirectory contains the raw data files (IPB) and
their corresponding log files. In the example presented above, it would contain:
H228X007.IPB, H228X007.OBS, H228X007.RDI. Access to this directory and to the
raw data files is automatically handled by CLIC.
- 5.
- DATA: Most of the time this directory is empty. However,
it can contain some IPB files and their corresponding log files. Like in the case of
tmp/DATA, its use is transparent. The reducer does not need to know the exact
location of the raw data files on her/his account. CLIC handles it for him/her.
Note that only the directories reports, headers and maps are saved on
CDroms by the automatic procedure savproj.
Next: 11.1.2 Before starting the
Up: 11.1 Introduction
Previous: 11.1 Introduction
S.Guilloteau
2000-01-19