To calibrate your data, you need to do the following actions leading to the output
calibration, in order:
- 1.
- SELECT: Select the calibration parameters
- 2.
- PHCOR: Radiometric phase correction, equivalent to a
``Monitor 0'', see A.Dutrey lecture.
- 3.
- RF: Radio Frequency calibration
- 4.
- PHASE: Instrumental phase calibration versus time
- 5.
- EFF: Efficiency (Jy/K) calibration, to determine the
flux densities of the amplitude calibrator. The inputs ``R1 Fluxes'' and ``R2 Fluxes'' should be used here.
- 6.
- AMP: Amplitude calibration versus time
- 7.
- PRINT: To produce the LaTeX and PostScript files
containing the calibration curves (e.g.
28-feb-2001-x007.ps).
By typing GO, all the actions listed above are done sequentially. The reducer
has just to type continue under CLIC (or use the ``Continue'' button in the
top left menu) at each step of the calibration process.